Skip to main content

INCORPORATING

HAMBURG GETS DAMEN MOBILE BWTS

Friday, November 29, 2019 

German maritime waste specialist Jongen has taken delivery of a Damen InvaSave 300 mobile ballast water treatment system (BWTS), which enables it to offer IMO-certified ballast water treatment services to ship operators needing to comply with the latest ballast water regulations that came into effect on 8 September 2019.

Jongen delivers waste oil, waste water, and the waste removal services for maritime traffic in the Port of Hamburg. The company’s services include the cleaning of the ships’ storage tanks and machinery along with the management and cleaning of oil spills. The addition of the Damen InvaSave to Jongen’s equipment portfolio reflects its expansion into ballast water treatment services.

Julia Dettmer, director of Jongen said: “We believe that Hamburg stands out from the other European ports by offering a mobile state-of-the-art ballast water treatment system operated by Jongen. The Invasave 300 is Hamburg’s answer to the new regulation of the IMO BMW Convention in order to prevent the transfer of harmful aquatic organisms.”

Damen’s InvaSave 300 is an IMO-certified BWTS, certified to treat ballast water without any holding time. Suitable for outbound and inbound vessels, it treats ballast water to IMO-D2 standards in as single pass, using no chemicals to eliminate invasive organisms from ballast water.

The IMO Ballast Water Management Convention stipulates that vessels built before 8 September 2017 must be able to comply with regulations by the time of their first International Oil Pollution Prevention (IOPP) renewal survey. This date falls on or after 8 September 2019.

Operating as an external unit, the InvaSave 300 is housed in a standard container.

Matthijs Schuiten, product manager, Damen Green Solutions said: “Because InvaSave fits on a trailer, workboat or barge, and no storage for holding time is required, operators can easily move it to where it is needed. The sheer mobility of InvaSave means that ship owners calling on Jongen’s new ballast water treatment services in the Port of Hamburg can keep their downtime to a minimum. This includes downtime during port calls, as well as the downtime needed for retrofitting an onboard ballast water treatment system.”

Reader Comments (0)

There are currently no comments on this article. Why not be the first and leave your thoughts below.

Leave Your Comment

Please keep your comment on topic, any inappropriate comments may be removed.

Return to index

Web Analytics